SECTION V: Troubleshooting
TM 9-2350-256-20
WARNING
Remove all jewelry such as rings, dog tags,
bracelets, etc. If jewelry contacts a metal
surface a direct short may result in instant
heating of tools, damage to equipment, and
injury or death to personnel.
K
Reconnect wire 1 (from socket D) to generator cutout
switch. Disconnect wire 1 (from socket C) from
generator cutout switch. Place red lead of
multimeter on generator cutout switch and black lead
to ground. Turn MASTER switch on, open generator
cutout switch and check for voltage. Turn MASTER
switch OFF, close generator cutout switch. If voltage
is present, repair/replace wire 1 of bilge pump main
power wiring harness (see paragraph 6-84). If voltage
is not present, replace generator cutout switch (see
paragraph 6-9).
2-129