SECTlON V: TROUBLESHOOTINGTM 9-2350-256-20WARNINGRemove all jewelry such as rings, dog tags,bracelets, etc. If jewelry contacts a metalsurface a direct short may result in instantheating of tools, damage to equipment, andinjury or death to personnel.D Reconnect flasher system panel wiring harness tolamp socket. Remove two screws (1), twolockwashers (2), two flat washers (3), and rearintermediate right access floor plate (4).Disconnect flasher system panel wiring harness athydraulic reservoir disconnect. Place red lead ofmultimeter in socket A of wire 663 and black lead toground. Turn MASTER switch on, place powercontrol lever switch in ON position, and check forvoltage. Turn MASTER switch and power controllever switch OFF. If voltage is present, go to step E.If voltage is not present, repair/replace wire 663 offlasher system panel wiring harness fromhydraulic oil high temperature lamp to hydraulicreservoir disconnect (see paragraph 6-48).E Reconnect flasher system panel wiring harness tohydraulic reservoir disconnect. Disconnect wire 663from high temperature switch on hydraulicreservoir. Place red lead of multimeter in wire 663and black lead to ground, turn MASTER switch on,place power control lever switch in ON position,and check for voltage. Turn MASTER switch andpower control lever switch OFF. If voltage ispresent, replace high temperature switch (seeparagraph 12-8). If voltage is not present,repair/replace wire 663 of hydraulic oiltemperature transmitter wiring harness (seeparagraph 6-88).2-345
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business