SECTlON V: TROUBLESHOOTINGTM 9-2350-256-20WARNINGRemove all jewelry such as rings, dog tags ,bracelets, etc. If jewelry contacts a metalsurface a direct short may result in instantheating of tools, damage to equipment, andinjury or death to personnel.F Reconnect flasher system panel wiring harness tohydraulic reservoir disconnect. Disconnect wire 664from hydraulic oil temperature transmitter (seeparagraph 12-8). Place red lead of multimeter inwire 664 and black lead to ground. Turn MASTERswitch on and check for voltage. Turn MASTERswitch OFF. If voltage is present, replacehydraulic oil temperature transmitter (seeparagraph 12-8). If voltage is not present,repair/replace wire 664 from hydraulic reservoirdisconnect to hydraulic oil temperature transmitter(see paragraph 6-88).G Reconnect wire 325 of switch panel, radio, and bilgepump to bulkhead wiring harness from 15 A circuitbreaker. Open air inlet doors (TM 9-2350-256-10).Disconnect wire 48 pin A from bulkhead to masterrelay wiring harness. Place red multimeter lead insocket and black lead to ground. Turn MASTERswitch on and check for voltage. Turn MASTERswitch OFF. If voltage is present, repair/replaceswitch panel, radio, and bilge pump to bulkheadwiring harness (see paragraph 6-53). If voltage isnot present, troubleshoot master relay circuit (seeparagraph 2-19, master relay fails to operate).2-349