SECTION II: GAGES AND SWITCH PANELSTM 9-2350-256-207Remove six clamps (32) by removing two nuts (33) and two lockwashers (34) from each.8Remove each indicating meter (24 and 27 through 31) from front of gage panel (8).9Remove ID plates (35, 36, and 37) by removing two drivescrews (38) from each.10 Disconnect three connectors (39) from fuel selector switch (40).11 Remove fuel selector switch instruction plate (41) and fuel selector switch (40) from gage panel (8) byremoving two screws (42) and two lockwashers (43).6-21
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business