SECTION I: CHARGING/STARTING SYSTEM AND VEHICLE BATTERIESTM 9-2350-256-2010 Install access cover (1) using four screws (2) andfour new lockwashers (3).11 Close access door (see paragraph 9-51).NOTEFollow-on maintenance:Install air inlet doors(see paragraph 9-56)6-6 REPLACE VOLTAGE REGULATOR (SINGLE VOLTAGE) (11659111-1)THIS TASK COVERSa. Removalb. InstallationINITIAL SET-UPTools:Parts:Equipment Condition:Tool kit, general mechanic's Lockwasher (Appendix G,Air inlet doors removed (see(Appendix C, item 53)item 115)paragraph 9-56)WARNINGBe certain MASTER switch is OFF when working on electrical system to avoid electrical shock and bums.NOTEA single voltage regulator may be used in dual voltage regulators as a replacement for the mainengine regulator only.a. REMOVAL1Disconnect two connectors (1).2Disconnect ground strap (2) by removing screw (3)and lockwasher (4).3Remove voltage regulator (5) by removing fourscrews (6) and four flat washers (7).b. INSTALLATION1Install voltage regulator (5) using four flat washers(7) and four screws (6).2Connect ground strap (2) using new lockwasher (4)and screw (3).3Connect two connectors (1).NOTEFollow-on maintenance:Install air inlet doors(see paragraph 9-56)6-17
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business