SECTION II: GAGES AND SWITCH PANELSTM 9-2350-256-20WARNINGBe certain MASTER switch is OFF when working on electrical system to avoid electrical shock and bums.a. REMOVAL1Remove ground strap (1) by removing two screws(2) and three lockwashers (3).2Disconnect tachometerconnector (4) andspeedometer connector (5).3Remove three screws (6) and three lockwashers (7).4Pull gage panel (8) forward and disconnect wiringharness (9).5Remove wiring harness (10) by removing fourscrews (11) and four lockwashers (12).6Remove gage panel (8).NOTEScrew (2) and lockwasher (3) wereremoved with ground strap (1).7Remove mounting bracket (13) by removing threescrews (14) and three lockwashers (156-19