CHAPTER 6: MAINTENANCE OF ELECTRICAL SYSTEMS AND CIRCUITS TM 9-2350-256-206-17 REPLACE/REPAIR POWER CONTROL LEVER SWITCH--ContinuedWARNINGBe certain MASTER switch is OFF when working on electrical system to avoid electrical shock and bums.a. REMOVAL1 Disconnect two connectors (1).2 Remove power control lever switch (2) from hydraulic system control panel (3) by removing four screws (4)and four lockwashers (5).3 Disconnect contact assembly (6) from sensitive switch (7).b. DISASSEMBLYDisassemble two lead assemblies (see Chapter 6, Section VII).c. ASSEMBLYAssemble two lead assemblies (see Chapter 6, Section VII).d. INSTALLATION1 Connect contact assembly (6) to sensitive switch (7).2 Install power control lever switch (2) to hydraulic system control panel (3) using four screws (4) and four newlockwashers (5).3 Connect two connectors (1).6-50
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business