TM 9-2350-256-20
CHAPTER 6: MAINTENANCE OF ELECTRICAL SYSTEMS AND CIRCUITS
6-45 REPLACE/REPAIR GAGE PANEL TO BULKHEAD WIRING HARNESS (DUAL
VOLTAGE) (12322587)-Continued
6
Remove connector (5) from bulkhead disconnect
( 2 0 ) b y r e m o v i n g f o u r s c r e w s ( 2 1 ) , f o u r
lockwashers (22), and gasket (23).
7
Disconnect connector (6) from mechanical
transmission low oil pressure switch (24).
8
Remove ground lead (7) by removing bolt (25).
9
Disconnect connector (S) from fuel tank transmitter
(26)
10 Disconnect connector (9) from power control
switch (27).
11
Disconnect two connectors (10 and 11) from switch
panel to gage panel and miscellaneous switches
wiring harness (28).
6-96