TM 9-2350-256-20
CHAPTER 6:
MAINTENANCE OF ELECTRlCAL SYSTEMS AND ClRCUITS
6 - 46 REPLACE/REPAIR GAGE PANEL TO BULKHEAD WIRING HARNESS
(SINGLE VOLTAGE) (11671807)-Continued
6
Remove ground lead (5) from bulkhead (22) by
removing screw (23) and lockwasher (21).
7
Remove connector (6) from bulkhead disconnect
(22) by removing three screws (25), three
lockwashers (26), and gasket (27).
8
Disconnect connector (7) from mechanical
transmission low oil pressure switch (28).
9
Remove ground lead (8) by removing bolt (29).
10 Disconnect connector (9) from fuel tank transmitter
(30).
11 Disconnect connector (10) from power control
switch (31).
12 Disconnect two connectors (11 and 12) from switch
panel to gage panel and miscellaneous switches
wiring harness (32).
6 - 1 0 0
Change 1