TM 9--2350--292--10
0101 00--29
PREVENTIVE MAINTENANCE CHECKS AND SERVICES INCLUDING
LUBRICATION INSTRUCTIONS -- CONTINUED
0101 00
TABLE 3 PREVENTIVE MAINTENANCE CHECKS AND SERVICES, AFTER--CONTINUED
Item No.
Not Fully Mission
Capable If:
CREWMEMBER
Procedure
LOCATION
Item toCheck/
Service
Interval
8 cont
After
Hydraulic
Reservoir Oil
Level --
Continued
If required, remove filler cap and add proper
grade oil (Table 6, WP 0101 00) to bring oil
level above DANGER mark. Insert bayonet
gauge. Start main engine (WP 0012 00)
and operate hydraulic system until hydraulic
oil is at operating temperature. Shut off
main engine (WP 0019 00). Remove
bayonet gauge and verify that oil level, on
the bayonet gauge, reaches the lower FULL
mark with the boom down or the upper
FULL mark with the boom up. If required,
remove filler cap and add oil. Install filler
cap and bayonet gauge. Recheck oil level.
Install subfloor plate (WP 0036 00).
Class III oil leaks.
BOOM UP FULL HOT BOOM DOWN
DANGER
SUBFLOOR ACCESS PLATE
BAYONET GAUGE
FILLER CAP