TM 9--2350--292--20--1
0213 00--4
TURBOCHARGER DUST DETECTOR SYSTEM REPLACEMENT --
CONTINUED
0213 00
Operational Test
1. Remove dust and dirt from filter strip cover (1) and compressor housing (2).
2. Loosen three captive screws (3) securing filter strip cover (1) to compressor housing (2). Do not remove cover
(1).
3. Insert 1--in. wide (25.4 mm) strip of nonporous material (plastic, celluloid, etc) over filter strip (4).
4. Tighten three captive screws (3).
5. Start engine (TM 9--2350--292--10). Apply vehicle brakes. Place transmission in high gear. Operate engine at
1800 to 1900 rpm for no more than 30 seconds. Observe SYSTEM WARNING lamp (5) and TURBO DUST DE-
Tector warning lamp (6).
6. If SYSTEM WARNING (5) and TURBO DUST DETector (6) warning lamps light, system is operational. If SYS-
TEM WARNING (5) and TURBO DUST DETector (6) warning lamps do not light, check to see if dust detector
pressure switch (7) (red plunger visible through plastic cover on pressure switch) tripped. If pressure switch (7) is
tripped, perform Troubleshooting (WP 0131 00). If pressure switch (7) did not trip, repeat step 5 to verify. If pres-
sure switch (7) still does not trip, replace dust detector pressure switch (7).
Figure 23
2
3
1
4
7
5
6