TM 9--2350--292--20--10221 00--3FUEL/WATER SEPARATOR OPERATION TESTS -- CONTINUED0221 00Manual Drain Test--ContinuedCAUTIONDo not damage fuel/water separator gasket when remov-ing cover. Failure to comply will result in leaks to the fuel/water separator.11. Remove eight screws (15), eight lockwashers (16), eight flat washers (17) and fuel/water separator cover (18).12. Add fuel to fuel/water separator (1) until fuel leaks from upper sensor probe (2) hole. Install screw (12).13. Install fuel/water separator cover (18) with eight screws (15), eight lockwashers (16) and eight flat washers (17).14. Open bleed cap (10).15. Place suitable metal container under manual drain outlet (19), open manual drain valve and allow a small amountof fluid to drain into container.16. If fluid does not drain, check drain valve and lines for obstructions. Remove obstructions or repair damaged drainlines or drain valve (WP 0219 00). Repeat Manual Drain Test.17. If fluid does drain, perform Automatic Drain Test.Figure 29SUITABLEMETAL CONTAINER1101918171615122