TM 9--2350--292--20--10221 00--10FUEL/WATER SEPARATOR OPERATION TESTS -- CONTINUED0221 00Sequential Drain Test--ContinuedWARNINGDo not allow upper and lower sensor probes to come incontact with each other or with metal container. Do nottouch probes. Failure to comply may result in electricalshock, inaccurate test results or damage to equipment.6. Hold tip of lower sensor probe (3) in water in suitable metal container.NOTESteps 7 through 10 must be completed within 15 sec-onds.7. Hold tip of upper sensor probe (2) in water in suitable metal container and check if fluid starts draining from sole-noid drain valve tube (20).8. Remove tip of upper sensor probe (2) from water in suitable metal container and check if fluid keeps draining fromsolenoid drain valve tube (20).9. Remove tip of lower sensor probe (3) from water in suitable metal container before 15 seconds have gone by fromtime of placing the probe in water and check if fluid stops draining from solenoid drain valve tube (20).Figure 29SUITABLE METALCONTAINERS2032(+)(--)