TM 9--2350--292--20--10221 00--12FUEL/WATER SEPARATOR OPERATION TESTS -- CONTINUED0221 00Sequential Drain Test--Continued11. Disconnect black wire (--) (27) and red wire (+) (26) from positive (+) and negative (--) terminals of24 V dc power source.12. Disconnect fuel/water separator test harness connector (24) from left control box receptacle (25) at fuel/waterseparator control box (22).13. Disconnect jumper wire (23) from negative (--) side of 24 V dc power source and from suitable metal container.14. Remove suitable metal container from under solenoid drain valve tube (20).15. Connect engine electrical harness (21) connector to fuel/water separator control box (22).Figure 29SUITABLE METALCONTAINERS24V dc2122252320(+)(--)262724