TM 9--2350--292--20--10288 00--5BATTERY, BATTERY TRAY AND BATTERY TERMINAL REPLACEMENT --CONTINUED0288 00Installation--ContinuedWARNINGWhen installing batteries, failure to observe proper bat-tery polarity can cause a short circuit and possible batteryexplosion resulting in injury to personnel and damage toequipment.NOTEUse storage battery carrier to aid in transporting batteries.3. Install six batteries (17) on two battery trays. Place batteries as shown in illustration with positive (+) and negative(--) posts at indicated positions.4. Hook two screws (15) on battery tray (16) and install two battery clamps (14), two flat washers (13), two new lock-washers (12) and two nuts (11).5. Install battery clamp (10) with screw (7), new lockwasher (8) and flat washer (9).Figure 102111213141615171517171410987131211