TM 9--2350--292--20--10288 00--6BATTERY, BATTERY TRAY AND BATTERY TERMINAL REPLACEMENT --CONTINUED0288 00Installation--ContinuedNOTEEnsure battery terminals are installed with identificationmarkings (P or +) or (N or --) facing up. Terminals withthe P or + marking are installed on the positive (+) batteryposts and terminals with the N or -- marking are installedon the negative (--) battery posts.6. Install 12 terminal covers (6) on battery posts.7. Install six positive (P or +) battery terminals (4) on six positive (+) battery posts. Install six negative(N or --) battery terminals (4) on six negative (--) battery posts. Position battery terminals (4) as shown in illustra-tion to permit fastening all lead assemblies when reconnecting battery power.8. When terminals (4) are properly positioned, tighten collared nut (5) until terminals (4) are secured to posts.9. Connect three lead assemblies 3W266 (1) by inserting screw (3) through battery terminal (4). Install lead assembly (1)over screw (3) and tighten securely with nut (2).Figure 1021234444455555452123445521234455245456666666NOTEFOLLOW--ON MAINTENANCE:Connect battery power (WP 0256 00)END OF TASK