TM 9--2350--292--20--10290 00--3WIRING HARNESS AND CABLE REPAIR -- CONTINUED0290 00CRIMPED TERMINALS -- CONTINUEDAssembly1. Strip cable insulation equal to depth of terminal (1) well.2. Push cable (2) against end of terminal (1) well and crimp.3. Apply epoxy to exposed end of wire (3)213TERMINAL TYPE CABLE CONNECTORSDisassemblyCut and discard connector.Assembly1. Strip cable insulation equal to depth of terminal well.2. Slide insulator (1) over cable (2).3. Insert cable (2) into terminal (3) well and crimp.4. Slide insulator (1) over crimped end of terminal (3).123FEMALE CABLE CONNECTOR WITH WASHERDisassemblyCut and discard connector.Assembly1. Strip cable insulation approximately 1/8 inch (3.2 mm).2. Slide shell (1) and washer (2) over cable (3).3. Place cable (3) in cylinder end of terminal (4).4. Slide shell (1) and washer (2) over terminal (4).1243