TM 9--2350--292--20--1
0290 00--3
WIRING HARNESS AND CABLE REPAIR -- CONTINUED
0290 00
CRIMPED TERMINALS -- CONTINUED
Assembly
1. Strip cable insulation equal to depth of terminal (1) well.
2. Push cable (2) against end of terminal (1) well and crimp.
3. Apply epoxy to exposed end of wire (3)
2
1
3
TERMINAL TYPE CABLE CONNECTORS
Disassembly
Cut and discard connector.
Assembly
1. Strip cable insulation equal to depth of terminal well.
2. Slide insulator (1) over cable (2).
3. Insert cable (2) into terminal (3) well and crimp.
4. Slide insulator (1) over crimped end of terminal (3).
1
2
3
FEMALE CABLE CONNECTOR WITH WASHER
Disassembly
Cut and discard connector.
Assembly
1. Strip cable insulation approximately 1/8 inch (3.2 mm).
2. Slide shell (1) and washer (2) over cable (3).
3. Place cable (3) in cylinder end of terminal (4).
4. Slide shell (1) and washer (2) over terminal (4).
1
2
4
3