TM 9--2350--292--20--1
0290 00--8
WIRING HARNESS AND CABLE REPAIR -- CONTINUED
0290 00
TYPICAL FEMALE--TYPE PLUG WITH RIDGED LOCKING NUT
Disassembly
1. Heat boot (1) on shell assembly (2) and roll back on cable (3).
2. Unscrew nut (4) from shell assembly (2) and slide back on cable (3).
3. Drive socket contacts (5) out through rear of shell (6) with socket extractors.
4. Unsolder or cut leads from socket contacts (5).
Assembly
1. Strip cable (3) insulation equal to depth of wells in socket contacts (5).
2. Slide nut (4) onto cable (3).
3. Insert cable (3) leads into wells of socket contacts (5) and solder or crimp.
4. Push socket contacts (5) into shell (6) from rear until seated.
5. Screw nut (4) onto shell assembly (2).
6. Apply a thin even layer of adhesive to shell assembly (2) and roll boot (1) onto shell assembly (2).
6
5
4
3
1
2