TM 9--2350--292--20--1
0290 00--9
WIRING HARNESS AND CABLE REPAIR -- CONTINUED
0290 00
TYPICAL MALE--TYPE PLUG WITH RIDGED LOCKING NUT
Disassembly
1. Heat boot (1) on shell assembly (2) and roll back on cable (3).
2. Unscrew nut (4) from shell assembly (2) and slide back on cable (3).
3. Drive pin contacts (5) out through rear of shell (6) with pin extractors.
4. Unsolder or cut cable (3) leads from pin contacts (5).
Assembly
1. Strip cable (3) insulation equal to depth of wells in pin contacts (5).
2. Insert cable (3) leads into wells of pin contacts (5) and solder or crimp.
3. Push pin contacts (5) into shell (6) from rear until seated.
4. Screw nut (4) onto shell assembly (2).
5. Apply a thin even layer of adhesive to shell assembly (2) and roll boot (1) onto shell assembly (2).
6
5
4
3
1
2