Home
Download PDF
Order CD-ROM
Order in Print
ENGINE CRANKS AT NORMAL SPEED BUT WILL NOT START (cont) - TM-9-2350-292-20-1_238
ENGINE CRANKS AT NORMAL SPEED BUT WILL NOT START (cont) - TM-9-2350-292-20-1_240
TM-9-2350-292-20-1 Carrier Ammunition Tracked M992A1(NSN 2360-01-362-3021) EIC:AE6 Manual
Page Navigation
190
191
192
193
194
195
196
197
198
199
200
TM 9--2350--292--20--1
0042 00--6
ENGINE CRANKS AT NORMAL SPEED BUT WILL NOT START -- CONTINUED
0042 00
no
yes
Does indicator remain lit?
1. Reconnect harness 4W101 lead 54A to
interlock switch.
2. Remove switch panel (WP 0242 00) and
reconnect ground strap to switch panel.
3. Disconnect harness 4W101 P1 from switch
panel.
4. Turn MASTER switch ON
(TM 9--2350--292--10).
5. Turn MASTER switch OFF
(TM 9--2350--292--10).
Replace interlock
switch (WP 0701 00).
Verify fault is cor-
rected.
no
yes
Replace fuel shut-
off switch (WP
0242 00). Verify
fault is corrected.
Does indicator remain lit?
J
1. Disconnect harness 4W101 lead 54A from
indicator side of fire extinguisher fuel line
interlock switch.
2. Turn MASTER switch ON
(TM 9--2350--292--10).
3. Turn MASTER switch OFF
(TM 9--2350--292--10).
K
CONTINUED FROM STEP I
CONTINUED ON NEXT PAGE
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business