TM 9--2350--292--20--1
0042 00--2
ENGINE CRANKS AT NORMAL SPEED BUT WILL NOT START -- CONTINUED
0042 00
CONTINUED FROM STEP B
CONTINUED ON NEXT PAGE
Is there a free pin fit?
C
no
yes
Adjust connector
(WP 0216 00). Verify
fault is corrected.
1. Place manual fuel shutoff handle in the ON
position (TM 9--2350--292--10).
2. Remove cotter pin from one end of connector
link between control cable and engine shutoff
lever.
3. Place engine shutoff lever in the on position
(TM 9--2350--292--10).
4. Check connector link for a free pin fit.
Does electric fuel pump make a noise?
no
yes
D Turn MASTER switch and intank fuel pump switch
ON and OFF (TM 9--2350--292--10).
Go to step P. (WP 0039 00)
FORWARD