TM 9--2350--292--20--1
ENGINE FAILS TO CRANK WHEN STARTER SWTICH IS PRESSED --
CONTINUED
0041 00
CONTINUED FROM STEP AF
Is voltage present?
1. Reconnect 3W202 connector to low voltage
starter protection module.
2. Turn MASTER switch ON and engage
START switch (TM 9--2350--292--10).
3. Place multimeter red lead on lead 14D
starter terminal and black lead to ground.
Check for voltage.
4. Turn MASTER switch OFF
(TM 9--2350--292--10).
AG
no
yes
Replace starter (WP
0240 00). Verify fault is
corrected.
Replace low voltage
starter protection mod-
ule (WP 0241 00).
Verify fault is corrected.
END OF TASK
0041 00--15/16 blank