TM 9--2350--292--20--10042 00--8ENGINE CRANKS AT NORMAL SPEED BUT WILL NOT START -- CONTINUED0042 00Is resistance measured with black lead to ground lowand with red lead to ground high?NCONTINUED FROM STEP M1. Disconnect diode from lead 4W152 J1 CKT 54connector from ground.2. Disconnect harness 4W103 P1 from gaugepanel.3. Place multimeter red lead in harness 4W152 J1gauge panel connector pin B and black lead toground. Measure resistance.4. Place multimeter black lead on cathode end ofdiode and red lead to ground. Measureresistance.noyesReplace FIRE EXTIN-GUISHERS ENGINESHUTOFF indicator(WP 0243 00). Verifyfault is corrected.Replace diode andleads from indicator toground (WP 0243 00).Verify fault is corrected.END OF TASK
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business