TM 9--2350--292--20--10044 00--2ENGINE CRANKS SLOWLY BUT WILL NOT START -- CONTINUED0044 00Is VTM reading at least 18 V dc?noyesCONTINUED ON NEXT PAGEPerform STE--ICE--R test 69(TM 9--4910--571--12&P) and record results.noyesIs VTM reading higher than 1.8 V dc?CONTINUED FROM STEP BPerform STE--ICE--R test 73(TM 9--4910--571--12&P) and record results.noyesIs VTM reading less than 8.33 milliohms?CDEPerform STE--ICE--R test 68(TM 9--4910--571--12&P) and record results.Check battery terminalsand connections for corrosion,check electrolyte level,recharge batteries(TM 9--2350--292--10/WP 0187 00) and run testagain. If test fails, run test 89(TM 9--4910--571--12&P).Perform test 67 with controlfunction 02(TM 9--4910--571--12&P).If test passes, repair (WP0290 00) or replace (WP0333 00) harness 4W800.Verify fault is corrected.Perform test 91(TM 9--4910--571--12&P) onharness 4W800. If harness isfaulty, repair (WP 0290 00) orreplace (WP 0333 00) asnecessary and verify fault iscorrected.
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business