TM 9--2350--292--20--1ENGINE CRANKS SLOWLY BUT WILL NOT START -- CONTINUED0044 00Perform battery test (WP 0187 00)noyesAre batteries serviceable?CONTINUED FROM STEP ERecharge or replace batteriesas necessary(WP 0187 00/WP 0288 00).Verify fault is corrected.Perform STE--ICE--R test 70(TM 9--4910--571--12&P) and record results.noyesFIs VTM reading at least 18 V dc?GPerform STE--ICE--R test 71(TM 9--4910--571--12&P) and record results.Is VTM reading between 200 and 900 amps?noyesHPerform tests 67 and 69using function 02(TM 9--4910--571--12&P).If tests are passed, replacestarter (WP 0240 00). Verifyfault is corrected.Replace starter (WP0240 00). Verify faultis corrected.Troubleshoot starterprotect module (WP0041 00) Step Z.CONTINUED FROM STEP AEND OF TASK0044 00--3/4 blank