TM 9--2350--292--20--1
0045 00--2
ENGINE FAILS TO SHUTOFF WHEN SHUTOFF SWITCH IS ACTIVATED --
CONTINUED
0045 00
CONTINUED FROM STEP B
CONTINUED ON NEXT PAGE
Is 24 V dc present?
C
no
yes
Repair (WP 0290 00) or
replace (WP 0317 00)
harness 4W105. Verify
fault is corrected.
1. Disconnect harness 4W105 P1 from switch
panel.
2. Turn MASTER switch ON
(TM 9--2350--292--10).
3. Place multimeter red lead on socket B of
harness 4W105 P1 and black lead to ground.
Check for voltage.
4. Turn MASTER switch OFF
(TM 9--2350--292--10).
Is continuity present?
no
yes
D 1. Disconnect lead 10 from CB2.
2. Place one multimeter lead on harness 4W151
J4 pin E and other lead in lead 10 connector
socket. Check for continuity.
Repair (WP 0290 00) or
replace (WP 0242 00)
lead 10 to CB2. Verify
fault is corrected.