TM 9--2350--292--20--10045 00--2ENGINE FAILS TO SHUTOFF WHEN SHUTOFF SWITCH IS ACTIVATED --CONTINUED0045 00CONTINUED FROM STEP BCONTINUED ON NEXT PAGEIs 24 V dc present?CnoyesRepair (WP 0290 00) orreplace (WP 0317 00)harness 4W105. Verifyfault is corrected.1. Disconnect harness 4W105 P1 from switchpanel.2. Turn MASTER switch ON(TM 9--2350--292--10).3. Place multimeter red lead on socket B ofharness 4W105 P1 and black lead to ground.Check for voltage.4. Turn MASTER switch OFF(TM 9--2350--292--10).Is continuity present?noyesD 1. Disconnect lead 10 from CB2.2. Place one multimeter lead on harness 4W151J4 pin E and other lead in lead 10 connectorsocket. Check for continuity.Repair (WP 0290 00) orreplace (WP 0242 00)lead 10 to CB2. Verifyfault is corrected.