TM 9--2350--292--20--1
0045 00--4
ENGINE FAILS TO SHUTOFF WHEN SHUTOFF SWITCH IS ACTIVATED --
CONTINUED
0045 00
Is continuity present?
no
yes
G
Is 24 V dc present?
1. Reconnect leads 10 and 54 to CB2.
2. Disconnect lead 54 from switch S3 at
receptacle side.
3. Place one multimeter lead on each switch S3
connector. Check for continuity.
H
no
yes
CONTINUED FROM STEP F
Replace switch S3
(WP 0242 00). Verify
fault is corrected.
1. Reconnect harness 4W101 P1 to switch panel.
2. Disconnect harness 3W132 P1 at bulkhead.
3. Turn MASTER switch and FUEL SHUTOFF
switch ON (TM 9--2350--292--10).
4. Place multimeter red lead in harness 3W132 P1
bulkhead receptacle socket D and black lead to
ground. Check for voltage.
5. Turn MASTER switch and FUEL SHUTOFF
switch OFF (TM 9--2350--292--10).
CONTINUED ON NEXT PAGE
Repair (WP 0290 00) or
replace (WP 0315 00)
harness 4W101. Verify
fault is corrected.
Repair (WP 0290 00) or
replace (WP 0242 00)
lead 54 from switch S3 to
harness 4W151 J4 pin B.
Verify fault is corrected.
CONTINUED FROM STEP B