ENGINE BATT/GEN GAUGE READS IN YELLOW OR LOWER RED REGION WITH MAIN ENGINE RUNNING (cont) - TM-9-2350-292-20-1_384
ENGINE BATT/GEN GAUGE READS IN GREEN BUT ENGINE ACCESSORIES FAIL TO OPERATE
TM-9-2350-292-20-1 Carrier Ammunition Tracked M992A1(NSN 2360-01-362-3021) EIC:AE6 Manual
Page Navigation
336
337
338
339
340
341
342
343
344
345
346
TM 9--2350--292--20--1
ENGINE BATT/GEN GAUGE READS IN YELLOW OR LOWER RED REGION
WITH MAIN ENGINE RUNNING -- CONTINUED
0082 00
Fault corrected.
Replace generator
(WP 0237 00). Verify
fault is corrected.
yes
no
AJ
Did BATT/GEN gauge read in green?
CONTINUED FROM STEP AI
1. Replace voltage regulator (WP 0239 00).
2. Reconnect connector to
generator
receptacle
J1 and reconnect harness 3W143 P1 to engine
disconnect.
3. Turn MASTER switch and FUEL PUMP switch
ON, turn
GENERATOR
switch to ON and start
engine (TM 9--2350--292--10).
4. Turn MASTER switch, FUEL PUMP switch and
GENERATOR switch OFF
(TM 9--2350--292--10).
END OF TASK
0082 00--13/14 blank