TM 9--2350--292--20--1
0082 00--11
ENGINE BATT/GEN GAUGE READS IN YELLOW OR LOWER RED REGION
WITH MAIN ENGINE RUNNING -- CONTINUED
0082 00
CONTINUED FROM STEP AC
CONTINUED ON NEXT PAGE
Is continuity present?
1. Disconnect receptacle J2 connector from
generator.
2. Place one multimeter lead on harness 3W202
J3 pin Z and other lead on generator connector
J2 socket C. Check for continuity.
AD
no
yes
Repair (WP 0290 00) or
replace (WP 0300 00)
harness 3W202. Verify
fault is corrected.
no
yes
Repair (WP 0290 00) or
replace (WP 0300 00)
harness 3W202. Verify fault
is corrected.
AE
Place one multimeter lead on harness 3W202 J3
pin S and other lead on generator connector J2
socket A. Check for continuity.
Is continuity present?
no
yes
Repair (WP 0290 00) or
replace (WP 0300 00)
harness 3W202. Verify
fault is corrected.
AF
1. Reconnect connector to generator receptacle
J2.
2. Disconnect receptacle J1 connector from
generator.
3. Place one multimeter lead on harness 3W202
J3 pin S and other lead on generator
connector J1 pin C. Check for continuity.
Is continuity present?