TM 9--2350--292--20--10082 00--10ENGINE BATT/GEN GAUGE READS IN YELLOW OR LOWER RED REGIONWITH MAIN ENGINE RUNNING -- CONTINUED0082 00CONTINUED FROM STEP AACONTINUED ON NEXT PAGEAB1. Reconnect harness 3W180 P1 to voltageregulator.2. Place one multimeter lead in harness 3W143P1 socket S and other lead to vehicle ground.Check for continuity.Is continuity present?noyesRepair (WP 0290 00) orreplace (WP 0336 00)ground lead. Verify faultis corrected.1. Remove powerpack (WP 0188 00).2. Install ground hop kit (WP 0189 00).3. Start engine (TM 9--2350--292--10).4. Place multimeter red lead on generator terminalB+ and black lead to ground. Check for voltage.5. Shut engine down (TM 9--2350--292--10).Is 28 V dc present?noyesRepair (WP 0290 00) orreplace (WP 0240 00)lead from terminal B+ toterminal B at enginestarter. Verify fault iscorrected.AC