TM 9--2350--292--20--10089 00--2SLOW OR NO HYDRAULIC COMPONENT OPERATION WITH HYDRAULICSELECTOR SET IN MAIN POSITION -- CONTINUED0089 00Is gauge pressure 80--140 psi?1. Install 0--300 psi dial pressure gauge in filtervalve manifold port CH4.2. Start main engine, energize hydraulics, andset engine speed to 1800 rpm(TM 9--2350--292--10). Observe gauge.3. Shut down hydraulics and main engine(TM 9--2350--292--10).noyesnoyesBCCONTINUED ON NEXT PAGEInspect hose from reservoir to charge pump forleaks, restrictions, and damage.Is hose free of leaks, restrictions, and damage?Go to Step F.Tighten leaking connections and removerestrictions. If restrictions cannot be re-moved or if hose is damaged, replace(WP 0583 00). Verify fault is corrected.CONTINUED FROM STEP AFORWARDWARNING