TM 9--2350--292--20--1
0089 00--2
SLOW OR NO HYDRAULIC COMPONENT OPERATION WITH HYDRAULIC
SELECTOR SET IN MAIN POSITION -- CONTINUED
0089 00
Is gauge pressure 80--140 psi?
1. Install 0--300 psi dial pressure gauge in filter
valve manifold port CH4.
2. Start main engine, energize hydraulics, and
set engine speed to 1800 rpm
(TM 9--2350--292--10). Observe gauge.
3. Shut down hydraulics and main engine
(TM 9--2350--292--10).
no
yes
no
yes
B
C
CONTINUED ON NEXT PAGE
Inspect hose from reservoir to charge pump for
leaks, restrictions, and damage.
Is hose free of leaks, restrictions, and damage?
Go to Step F.
Tighten leaking connections and remove
restrictions. If restrictions cannot be re-
moved or if hose is damaged, replace
(WP 0583 00). Verify fault is corrected.
CONTINUED FROM STEP A
FORWARD
WARNING