TM 9--2350--292--20--1
0097 00--12
BOOM FAILS TO OPERATE OR OPERATES ROUGHLY -- CONTINUED
0097 00
FORWARD
CONTINUED FROM STEP U
no
yes
CONTINUED ON NEXT PAGE
Is pressure at port A 440--625 psi?
Notify Direct Support
Maintenance.
V
Are hose and fittings free of leaks and damage?
no
yes
1. Remove subfloor plates 10, 11 and 12 (WP
0454 00).
2. Inspect hose and fittings from boom safety
valve to boom shutoff valve for leaks and
damage.
Tighten leaking connec-
tions. Replace dam-
aged fittings and hose
(WP 0576 00). Verify
fault is corrected.
Go to Step I.
CONTINUED FROM STEP U
Notify Direct Support
Maintenance.
CONTINUED FROM STEP T
W
Are hoses and fittings free of leaks and damage?
no
yes
1. Remove subfloor plates 10, 11, 12, 15, 18, 23,
31 and 32 (WP 0454 00).
2. Inspect hoses and fittings from boom safety
valve to stayline cylinders for leaks and
damage.
Tighten leaking connec-
tions. Replace dam-
aged hoses and fittings
(WP 0566 00). Verify
fault is corrected.
Verify fault is
corrected.