TM 9--2350--292--20--10109 00--2DOME LIGHT FAILS TO OPERATE -- CONTINUED0109 00CONTINUED FROM STEP BC1. Disconnect lead 38 from dome light.2. Turn MASTER switch ON(TM 9--2350--292--10).3. Place multimeter red lead in lead 38connector socket and black lead to ground.Check for voltage.4. Turn MASTER switch OFF(TM 9--2350--292--10).Is 24 V dc present?Repair (WP 0290 00) orreplace (WP 0317 00,WP 0327 00) harness4W105 (4W153). Verifyfault is corrected.noyesReplace switch(WP 0283 00). Verifyfault is corrected.END OF TASK