TM 9--2350--292--20--10111 00--2ONE OR BOTH WINCH LIGHTS FAIL TO OPERATE -- CONTINUED0111 00CONTINUED FROM STEP AnoyesRepair (WP 0290 00) orreplace (WP 0244 00)lead 518. Verify fault iscorrected.B1. Remove accessory panel (WP 0244 00).2. Turn MASTER switch ON(TM 9--2350--292--10).3. Place multimeter red lead on terminal 2 ofswitch S1 lead 518 connector and black lead toground. Check for voltage.4. Turn MASTER switch OFF(TM 9--2350--292--10).Is 24 V dc present?noyesReplace switch S1(WP 0244 00). Verifyfault is corrected.C 1. Turn WINCH LIGHT switch ON(TM 9--2350--292--10).2. Place one multimeter lead on each switch S1connector. Check for continuity.Is continuity present?CONTINUED ON NEXT PAGE