TM 9--2350--292--20--1ONE OR BOTH WINCH LIGHTS FAIL TO OPERATE -- CONTINUED0111 00CONTINUED FROM STEP CDIs continuity present?noyesRepair (WP 0290 00) orreplace (WP 0244 00)lead 518. Verify fault iscorrected.1. Disconnect harness 4W153 P1 fromaccessory panel.2. Place one multimeter lead on switch S1terminal 1 and other lead on pin G ofreceptacle J3. Check for continuity.Repair (WP 0290 00) orreplace (WP 0327 00)harness 4W153. Verifyfault is corrected.END OF TASK0111 00--3/4 blank