TM 9--2350--292--20--10112 00--2FIXED SPOTLIGHT FAILS TO OPERATE -- CONTINUED0112 00Is continuity present?Place one multimeter lead on black wire at lamp andthe other lead on black wire at binding electric.Check for continuity.noyesCD1. Remove spotlight handle (WP 0281 00).2. Place one multimeter lead on wire contact atbinding electric and the other lead on end ofcarbon rod at end of tube and housingassembly. Check for continuity.Is continuity present?Replace black wire lamp andbinding electric (WP 0281 00).Verify fault is corrected.noyesReplace tube and housingassembly (WP 0281 00).Verify fault is corrected.CONTINUED FROM STEP AE1. Remove two screws and cap from handleassembly.2. Remove one screw and drop switch out ofhandle assembly.3. Disconnect harness 4W153 wire 138 fromspotlight.4. Place one multimeter lead on switch wirecontact at switch and the other lead in socketend of switch wire. Check for continuity.Is continuity present?noyesReplace handleassembly (WP 0281 00).Verify fault is corrected.CONTINUED ON NEXT PAGE