TM 9--2350--292--20--10113 00--3TROUBLELIGHT FAILS TO OPERATE -- CONTINUED0113 00Is 24 V dc present?1. Open trouble light handle (WP 0280 00).2. Turn MASTER switch ON and trouble lightswitch ON (TM 9--2350--292--10).3. Place red multimeter lead on white wire terminalat trouble light switch and black lead to ground.Check for voltage.4. Turn MASTER switch and trouble light switchOFF (TM 9--2350--292--10).noyesDE 1. Turn MASTER switch ON(TM 9--2350--292--10).2. Place red multimeter lead on black wireterminal at trouble light switch and blacklead to ground.3. Turn trouble light switch ON(TM 9--2350--292--10).4. Check for voltage. (Push switch twice whilechecking for voltage.)Is 24 V dc present?Replace trouble light(WP 0280 00). Verifyfault is corrected.noyesReplace trouble lightswitch (WP 0280 00).Verify fault is corrected.CONTINUED FROM STEP CCONTINUED ON NEXT PAGE