TM 9--2350--292--20--1
0114 00--4
GAUGE PANEL LIGHTS FAIL TO OPERATE -- CONTINUED
0114 00
CONTINUED FROM STEP F
G Place one multimeter lead in harness 4W151 P1
socket B and other lead on harness 4W151 J4 pin
H. Check for continuity.
Is continuity present?
no
yes
Repair (WP 0290 00) or
replace (WP 0242 00)
harness 4W151. Verify
fault is corrected.
no
yes
Repair (WP 0290 00) or
replace (WP 0316 00)
harness 4W103. Verify
fault is corrected.
H
1. Reconnect harness 4W151 P1 to switch S8.
2. Place one multimeter lead in harness 4W105
P1 socket H and other lead in harness 4W103
P1 socket L. Check for continuity.
Is continuity present?
no
yes
Replace faulty lead 40 in
gauge panel (WP 0243 00).
Verify fault is corrected.
I
1. Disconnect lead 40 from light L4, L5 and L6
connectors.
2. Place one multimeter lead on harness 4W152
J1 pin L and other lead on each lead 40 light
connector pin (one at a time). Check
continuity.
Is continuity present at all three connectors?
Replace faulty panel light
socket(s) (WP 0243 00).
Verify fault is corrected.
CONTINUED FROM STEP B
END OF TASK