TM 9--2350--292--20--1
0114 00--3
GAUGE PANEL LIGHTS FAIL TO OPERATE -- CONTINUED
0114 00
CONTINUED FROM STEP C
D
CONTINUED ON NEXT PAGE
1. Disconnect harness 4W151 P1 from
switch S8.
2. Place one multimeter lead on harness
4W151 J4 pin N and other lead in harness
4W151 P1 socket F. Check for continuity.
Is continuity present?
no
yes
Repair (WP 0290 00) or
replace (WP 0242 00)
harness 4W151. Verify
fault is corrected.
no
yes
Replace S8 switch
(WP 0242 00). Verify
fault is corrected.
E 1. Place main light switch in any position except
OFF (TM 9--2350--292--10).
2. Place one multimeter lead on switch S8
receptacle pin F and other lead on pin A.
Check for continuity.
Is continuity present?
F
Is continuity present?
no
yes
Replace switch S8
(WP 0242 00). Verify
fault is corrected.
1. Place auxiliary switch in PANEL BRT position.
2. Place one multimeter lead on switch S8
receptacle pin A and other lead on pin B.
Check for continuity.