TM 9--2350--292--20--1
0123 00--5
EMERGENCY FLASHER LIGHT FAILS TO OPERATE -- CONTINUED
0123 00
CONTINUED FROM STEP H
no
yes
I
1. Reconnect lead 325 to CB5.
2. Disconnect lead 325 from panel receptacle
side of switch S6.
3. Place one multimeter lead on each switch S6
connector pin. Check for continuity.
Is continuity present?
Replace switch S6
(WP 0242 00). Verify
fault is corrected.
J
1. Reconnect lead 325 to CB5 side of switch S6.
2. Place one multimeter lead on harness 4W109
J3 pin E and other lead in switch S6 lead 325
connector socket. Check for continuity.
Is continuity present?
CONTINUED ON NEXT PAGE
Repair (WP 0290 00) or
replace (WP 0242 00 )
lead 325. Verify fault is
corrected.
Repair (WP 0290 00) or
replace (WP 0315 00)
harness 4W101. Verify
fault is corrected.
yes
no