TM 9--2350--292--20--1
0123 00--6
EMERGENCY FLASHER LIGHT FAILS TO OPERATE -- CONTINUED
0123 00
no
yes
K
1. Disconnect lead 325C from light L2.
2. Place one multimeter lead in harness 4W101
P2 socket C and other lead on light L2 lead
325C connector pin. Check for continuity.
Is continuity present?
CONTINUED FROM STEP D
CONTINUED ON NEXT PAGE
L 1. Reconnect harness 4W101 P1 to switch panel.
2. Connect a jumper wire from harness 4W101 P2
socket B to socket C.
3. Turn MASTER switch and FLASHER switch
ON (TM 9--2350--292--10). Observe flasher
indicator.
4. Turn MASTER switch and FLASHER switch
OFF (TM 9--2350--292--10).
Does indicator light?
Repair (WP 0290 00) or
replace (WP 0315 00)
harness 4W101. Verify
fault is corrected.
no
yes
Replace indicator
assembly (WP 0242 00).
Verify fault is corrected.