TM 9--2350--292--20--1
0129 00--4
FUEL GAUGE FAILS TO OPERATE PROPERLY -- CONTINUED
0129 00
G
Is continuity present?
CONTINUED FROM STEP F
no
yes
CONTINUED ON NEXT PAGE
1. Disconnect harness 4W103 P1 from gauge
panel.
2. Turn MASTER switch ON
(TM 9--2350--292--10).
3. Place multimeter red lead in harness 4W103
P1 socket K and black lead to ground. Check
for voltage.
4. Turn MASTER switch OFF
(TM 9--2350--292--10).
Go to Step L.