TM 9--2350--292--20--10129 00--5FUEL GAUGE FAILS TO OPERATE PROPERLY -- CONTINUED0129 00Is 24 V dc present?CONTINUED FROM STEP GnoyesCONTINUED ON NEXT PAGE1. Reconnect harness 4W103 P1 to gauge panel.2. Turn MASTER switch ON(TM 9--2350--292--10).3. Place multimeter red lead on harness 4W105P1 pin N and black lead to ground. Check forvoltage.4. Turn MASTER switch OFF(TM 9--2350--292--10).Repair (WP 0290 00) orreplace (WP 0314 00)harness 4W100. Verifyfault is corrected.Is continuity present?noyes1. Disconnect lead 10 from CB6 inside of switchpanel.2. Place one multimeter lead in harness 4W151J4 socket N and other lead in lead 10 CB6connector socket. Check for continuity.Repair (WP 0290 00) orreplace (WP 0242 00)lead 10 from harness4W151 J4 to CB6.Verify fault is corrected.noyes1. Remove switch panel from bracket(WP 0242 00) and reconnect ground strap toswitch panel.2. Disconnect harness 4W105 P1 from switchpanel.3. Place one multimeter lead in harness 4W103P1 socket K and other lead on harness 4W105P1 pin K. Check for continuity.Is continuity present?Repair (WP 0290 00) or replace(WP 0317 00) harness 4W105.Verify fault is corrected.HIJ