TM 9--2350--292--20--10129 00--10FUEL GAUGE FAILS TO OPERATE PROPERLY -- CONTINUED0129 00QIs continuity present?CONTINUED FROM STEP Pnoyes1. Reconnect lead 28 to switch S4.2. Disconnect harness 4W103 P1 from gaugepanel.3. Place one multimeter lead in lead 31 switch S4connector socket and other lead on harness4W152 J1 pin J. Check for continuity.Repair (WP 0290 00) or re-place (WP 0243 00) lead 31.Verify fault is corrected.RIs continuity present?noyes1. Reconnect lead 31 to switch S4.2. Disconnect harness 3W143 P2 from bulkheaddisconnect.3. Place one multimeter lead in harness 4W103P1 socket J and other lead in harness 3W143P2 receptacle socket A. Check for continuity.Repair (WP 0290 00) orreplace (WP 0316 00)harness 4W103. Verifyfault is corrected.SIs continuity present?noyes1. Reconnect harness 4W103 P1 to gauge panel.2. Disconnect lead 31 from liquid level transmitter.3. Place one multimeter lead in lead 31 liquid leveltransmitter connector socket and other lead onharness 3W143 P2 pin A. Check for continuity.Repair (WP 0290 00) orreplace (WP 0295 00)harness 3W143. Verifyfault is corrected.Replace liquid level trans-mitter (WP 0215 00).Verify fault is corrected.END OF TASK