TM 9--2350--292--20--1
0129 00--9
FUEL GAUGE FAILS TO OPERATE PROPERLY -- CONTINUED
0129 00
N
Is continuity present?
CONTINUED FROM STEP M
no
yes
CONTINUED ON NEXT PAGE
1. Reconnect lead 30 to switch S4.
2. Open subfloor plate 20 (WP 0454 00).
3. Disconnect lead 30 from liquid level transmitter.
4. Place one multimeter lead in harness 4W103
P1 socket M and other lead in lead 30 liquid
level transmitter connector socket. Check for
continuity.
Repair (WP 0290 00) or
replace (WP 0316 00)
harness 4W103. Verify
fault is corrected.
O
Does fuel gauge show proper reading?
no
yes
1. Reconnect lead 30 to liquid level transmitter.
2. Reconnect harness 4W103 P1 to gauge panel.
3. Turn MASTER switch ON
(TM 9--2350--292--10).
4. Turn MASTER switch OFF
(TM 9--2350--292--10).
Replace liquid level trans-
mitter (WP 0215 00).
Verify fault is corrected.
P
Is continuity present?
no
yes
1. Disconnect leads 28 and 31 from switch S4.
2. Turn selector switch to REAR position
(TM 9--2350--292--10).
3. Place one multimeter lead on each switch S4
connector pin. Check for continuity.
Replace switch S4
(WP 0243 00). Verify
fault is corrected.