TM 9--2350--292--20--1
0187 00--89
0187 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES INCLUDING
LUBRICATION INSTRUCTIONS -- CONTINUED
TABLE 3 PREVENTIVE MAINTENANCE CHECKS AND SERVICES
INCLUDING LUBRICATION INSTRUCTIONS, SEMIANNUALLY -- CONTINUED
ITEM
NO.
NOT FULLY
MISSION
CAPABLE
IF:
PROCEDURE
LOCATION
ITEM TO
CHECK/
SERVICE
INTERVAL
SEMIANNUALLY
INTERIOR
13
Hydraulic
System
WARNING
LUBRICANTS/
COMPONENTS
REFILL
CAPACITY
EXPECTED TEMPERATURE*
+40°F to --10°F
(+4°C to --23°C)
Above +32°F
(Above 0°C)
0°F to --65°F
(--17°C to --54°C)
OIL: Fire Retardant
Hydraulic Oil MIL--
H--46170
80 gal
(302.80L)
*For Arctic Operation, refer to FM 9--207
ALL TEMPERATURES
a. Replace hydraulic system oil filter
elements (1) (WP 0554 00). Add oil, if
required.
b. Inspect hydraulic lines, hoses and
fittings for leaks, damage and
deterioration (para 0568 00).
c. Operate system and check for
unusual noises or other defects.
d. Inspect hydraulic filter valve manifold
assembly (2) for leaks and damage.
Any Class III
leaks,
damaged or
missing
components.
1
2
FORWARD