TM 9--2350--292--20--1
0187 00--99
0187 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES INCLUDING
LUBRICATION INSTRUCTIONS -- CONTINUED
TABLE 3 PREVENTIVE MAINTENANCE CHECKS AND SERVICES
INCLUDING LUBRICATION INSTRUCTIONS, SEMIANNUALLY -- CONTINUED
ITEM
NO.
NOT FULLY
MISSION
CAPABLE
IF:
PROCEDURE
LOCATION
ITEM TO
CHECK/
SERVICE
INTERVAL
SEMIANNUALLY
INTERIOR
15
Hoist Winch --
Continued
k. Remove subfloor plate #13 (9)
(WP 0454 00).
l. Open hull drains (TM 9--2350--292--10).
Place suitable container (5 gallon capacity
minimum) under drain hull.
m. Rotate hoist winch drum (2) until oil
drain plug (10) in winch drum (2) is aligned
with hole in support end plate (11).
NOTE
Connection points for drain tool
assembly should be hand--
tightened only.
9
n. Install drain tool assembly
(item 115, WP 0717 00) (12) in
large threaded hole of hoist winch
drum (2). Ensure that shaft (13)
engages oil drain plug (10).
o. Connect drain tool assembly
(12) to hull drain hose (14).
p. Rotate oil drain tool assembly
shaft (13) until oil drains into
suitable container.
q. Remove sight gauge (15) and
vent/fill plug (16).
2
11
10
2
(HIDDEN)
16
15
12
14
13