TM 9--2350--292--20--2
0621 00--7
AUXILIARY POWER UNIT DUCTING REPLACEMENT (HATZ) -- CONTINUED
0621 00
Installation--Continued
7. Slide clamps (21 and 22) over air duct hose (23). Install air duct hose (23) over duct (24) and position clamp (22)
to hold air duct hose (23) to duct (24). Tighten clamp (22).
8. Attach the other end of the air duct hose (23) to duct (18). Position clamp (21) to hold air duct hose (23) to duct
(18) and tighten clamp (21).
9. Fasten duct (18) to auxiliary housing (14) with screw (19) and new lockwasher (20).
10. Attach bottom of duct (18) to auxiliary housing (14) with two screws (15), two new lockwashers (16) and two flat
washers (17).
22
14
17
16
15
18
20
19
21
24
23