TM 9--2350--292--20--2
0636 00--2
AUXILIARY POWER UNIT GENERATOR MOUNTING STUDS REPLACEMENT
-- CONTINUED
0636 00
Removal--Continued
CAUTION
To avoid damage to chaincase, do not drill more than
0.75 in. (1.91 cm) into stuBefore drilling, mark stud with
center punch to ensure drill bit is centered on stud.
NOTE
Perform the following steps only if stud cannot be re-
moved using procedures of step 1.
2. Using portable electric drill and twist drill set, drill pilot hole 0.75 in. (1.91 cm) deep in center of stud (1).
3. Tap screw remover into pilot hole and remove stud (1).
4. Inspect parts for damage and replace as required.
Installation
1. Apply adhesive to threads of stud (1).
2. Using stud inserter and remover, install stud (1) in chaincase (2).
Figure 343
1
2
NOTE
FOLLOW--ON MAINTENANCE:
Install APU generator (WP 0634 00)
END OF TASK