TM 9--2350--292--20--2
0635 00--6
AUXILIARY POWER UNIT GENERATOR REPLACEMENT (HATZ) --
CONTINUED
0635 00
Installation--Continued
6. Install two wires (20 and 21), with flat washer (19, supplied with generator) and new self--locking nut (18, supplied
with generator) on terminal B of generator (7).
7. Install wire (17), flat washer (16, supplied with generator) and new self--locking nut (15, supplied with generator)
on terminal A of generator (7).
8. Install wire (14), flat washer (13, supplied with generator) and new self--locking nut (12, supplied with generator)
on terminal D of generator (7).
9. Install two wires (10 and 11), three new lockwashers (9) and self--locking nut (8, supplied with generator) on termi-
nal E of generator (7).
10. After generator leads are installed, apply adhesive to all exposed electrical terminals.
14
13
12
21
18
19
20
15
16
17
8
10
9
9
11
7
7